检测报告
Insulating Rubber Sheet Breakdown Voltage Test – 6 mm Sample and Material Properties
The petrochemical industry report records physical property testing and a 31 kV breakdown voltage result for a submitted 6 mm sample.
This report covers a submitted 6 mm insulating rubber sheet sample. It records hardness, tensile strength and elongation results, plus a 31 kV breakdown voltage result against a 30 kV threshold from a subcontracted test. Breakdown voltage is not the product's stated working voltage. Read the full PDF for methods and sample-specific results.