Electrical insulation
Electrical Insulation Rubber Sheet Applications
Electrical insulating rubber matting for switchgear, substations and maintenance areas. Tell us whether your required working voltage is 5 kV, 10 kV, 15 kV, 35 kV or another value, and which IEC 61111:2009 documents you need.
Insulating Rubber Matting for Electrical Work Areas
Electrical insulating matting is used as floor covering in electrical work areas. We supply rubber mats and sheets in rolls and cut sizes for switchgear rooms, substations and maintenance areas. Buyers may specify 5 kV, 10 kV, 15 kV or 35 kV as their required working voltage. These are application requirements, not dielectric proof-test voltages.
We have multiple test reports for our electrical insulating matting. IEC 61111:2009 is the standard shown on the pictured Class 0 mat. For each quotation, we match the intended working voltage, AC or DC use, mat class and relevant test report to the product offered. The Class 0 marking in the photo applies to that particular mat; other voltage requirements need the corresponding class and documentation.
Information for Your Inquiry
- Required working voltage: 5, 10, 15, 35 kV or other
- AC or DC use and installation location
- IEC 61111:2009 class and test-report requirements
- Mat size, thickness, surface, quantity and cut format
| Product and document selection | Start with our Insulation Rubber Sheet. Confirm the proposed mat class, working-voltage limit and matching test report for the specified work area before ordering. |
|---|---|
| Quotation process | Send the working voltage, AC/DC conditions, dimensions, quantity and required IEC 61111:2009 documentation. We will identify the matching mat specification and provide the relevant report with the quotation. |
Electrical Insulating Mat Questions
Can I request a mat for 5 kV, 10 kV, 15 kV or 35 kV working voltage?
Yes. Tell us the required working voltage and whether the application is AC or DC. We will match it to the appropriate mat class and the documentation for the product offered.
Is working voltage the same as the dielectric test voltage?
No. Working voltage describes the intended electrical application. A dielectric test voltage is applied under a defined test procedure. The two values must not be used interchangeably.
Do you have IEC 61111:2009 test reports?
Yes. We have multiple test reports for electrical insulating matting. Ask for the report that corresponds to the mat class and specification in your quotation.